RS232 serial connector pin assignment
RS232 serial connector pin assignment

The RS232 connector was originally developed to use 25 pins. In this DB25 connector pinout provisions were made for a secondary serial RS232 communication channel. In practice, only one serial communication channel with accompanying handshaking is…

Selengkapnya >>

0
Idec / Izumi PLC’s
Idec / Izumi PLC’s

 Idec / Izumi PLC series FA2, FA2J and FA3J all require a special communication adapter for programming. This communication link adapter (CLA) is a small box that converts the RS232 electrical signals into a compatible level for the PLC. The cable…

Selengkapnya >>

0
Pin assignment for the Siemens S5 DB15 connector
Pin assignment for the Siemens S5 DB15 connector

On Siemens S5 PLC systems and peripherals, a DB15 connector is used for serial communications. This connector is present on CPUs, communication processors and operator panels, and in all cases the used pins and functionality slightly differ. The p…

Selengkapnya >>

0
Mitsubishi PLC cable layouts
Mitsubishi PLC cable layouts

 Melsec PLC’s from Mitsubishi can be connected to PC’s running Medoc programming software using various cables. Each different I/O module uses a different pin assignment. Not all Mitsubishi PLCs can be connected directly to a programming PC. The s…

Selengkapnya >>

0
Omron PLC cable layouts
Omron PLC cable layouts

 The PLCs from Omron can be connected to various peripheral equipment. Each device requires its own cable layout. Only the more common cables are shown here. DB9 RS232 programming cable DB25 RS232 programming cable CV500-CIF01 toolbus programming c…

Selengkapnya >>

0
Multiple Connect Databases in CodeIgniter
Multiple Connect Databases in CodeIgniter

 Multiple Connect Databases in CodeIgniterDatabase settingsFirst, you want to set the database settings at application/config/database.php. Below is my database settings for my two databases.…

Selengkapnya >>

0
Install MySQL FEDERATED engine
Install MySQL FEDERATED engine

 Install MySQL FEDERATED engineMenambahkan/Aktifkan Engines FEDERATED pada XAMPP1.Download MariaDB versi 10.6.xx dan extract letak kan di dalam folder xampp2.Masuk ke folder Xampp dan ubah folder mysql jadi mysql.old 3.Hasil extract MariaDB ubah menj…

Selengkapnya >>
 
 
Top